Study Guide – Cardiovascular Physiology
General Features of the Cardiovascular System
overview
- functions of the cardiovascular system
- maintenance of homeostasis
- amount of blood flow to each organ must be matched to the needs of the organ
- distribution of blood flow must be adjusted continuously and rapidly
- regulation of body temperature
- variation in blood flow to the skin
- increased temperature leads to increased peripheral blood flow
- transportation of hormones
- anatomical divisions of the cardiovascular system
- systemic circuit: left ventricle to body to right atrium
- pulmonary circuit: right ventricle to lungs to left atrium
- blood volume and distribution of blood between the circuits
- adult human volume
- 4-6 L total
- 70-75 mL blood / kg body weight
- measurement: Evan’s blue dye
- upon injection, binds to plasma proteins in the cardiovascular system
- known volume is injected, and after several minutes, blood sample is drawn and analyzed
- calculation:
- unequal blood distribution
- systemic: 80-85% of total
- pulmonary: 15-20% of total
autonomics in the nervous system
- parasympathetic
- M2 receptor
- effector: atrial muscle; cardiac nodal tissue (NOT present in ventricles)
- effect: contractile inhibition: slows heart rate, AP conduction velocity, and contractility
- mechanism: anti-β effects (↓ PKA via adenylate cyclase inhibition); ↑gK
- sympathetic
- α1 receptor
- effector: vascular smooth muscle (except coronary, cerebral, pulmonary circulation)
- effect: contraction: targeted vasoconstriction
- mechanism: PKC-induced ↑gCa and ↓gK, giving depolarization
- β1 receptor
- effector: cardiac muscle, nodal tissue
- effect: contractile: increases heart rate, AP conduction velocity, and contractility
- mechanism: PKA-induced ion channel and contractile protein phosphorylation
- β2 receptor
- effector: variable (sometimes present in heart, peripheral vasculature)
- effect: relaxation
- mechanism: PKA activation of Ca2+-dependent gK, giving hyperpolarization
basic anatomy of the systemic circulation
- vascular bed: set of blood vessels supplying blood to a given organ or type of tissue
- organization and order of flow: high to low pressure
- arterial tree: aorta, artery, arteriole, terminal arteriole
- capillary bed
- venous return: venule, vein, vena cava
- structures
- smooth muscle: higher content in high pressure vessels
- elastic tissue: higher content in high pressure vessels
- endothelial cells: line all vessels, including capillaries
- exchange: independent controls of vasoconstriction and vasodilation
- arterioles: regulated by sympathetic innervation
- precapillary sphincters: regulated by O2 tension, CO2 tension
- cross-sectional area
- varies immensely over different levels of circulation
- much larger in capillary beds
- larger area for exchange
- greater time for exchange (increased cross-sectional area means decreased velocity)
- systemic vascular beds: arrangement in parallel
- physiological advantages of parallel arrangement
- blood composition identical in each bed
- arterial pressure identical in each bed
- independent regulation of flow to each bed
- low resistance to flow vs. arrangement in series
- exceptions: arrangement in series
- portal circulations: specialized for point-point delivery of substances (hormones, nutrients)
- glomerular capillary beds: specialized for filtration of blood, reabsorption of salts and water
concepts and terms
- pressure
- pressure: form of energy driving cardiovascular blood flow
- sphygmomanometer: device commonly used to measure blood pressure in humans
- measurement of arterial blood pressure
- arterial blood pressure fluctuates in time, so multiple terms must be used
- systolic pressure: highest pressure achieved during the cardiac cycle (contraction phase)
- diastolic pressure: lowest pressure achieved during the cardiac cycle (relaxation phase)
- pulse pressure: arithmetic difference between systolic, diastolic pressure
- mean arterial blood pressure (MABP): average pressure during an entire cardiac cycle
- can be calculated by a measurement of area under the curve
- can be approximated as 1/3 of the pulse pressure, summed to diastolic pressure
- typical values
- males: 120/80 (systolic/diastolic)
- females: 110/70
- flow
- blood flow (Q): amount of blood flowing through a circuit per unit time
- equation:
- Q: blood flow
- ΔP: pressure gradient driving flow
- R: resistance to flow
- continuity of flow
- amount of blood flowing through any unique cross-sectional areas are identical
- deviations from continuity indicate disease, acute injury
- velocity of flow
- measurement: flux past a point in a circuit (cm/s)
- varies with cross-sectional area of the flow
- large arteries: 30-50 cm/sec
- capillaries: 0.1 cm/sec
- large veins: 15-20 cm/sec
Physiological Properties of Heart Muscle
automaticity
- automaticity: ability of the heart to spontaneously generate AP necessary for each beat
- pacemaker cells: automatic cells; drive pace of heart beat
- cardiac innervation: autonomic
- heart is not controlled via nerve-induced action potentials, as in α-motor neurons
- autonomic innervation regulates automaticity, force of muscle contraction
conduction or propagation of action potentials
- syncytium: collective; functional organization of heart
- mechanisms of propagation identical to those in unmyleinated neurons, skeletal muscle fibers
- APs pass readily from cell to cell, utilizing numerous gap junctions
- intercalated disc: specialized gap junction permitting local currents to flow from cell to cell
- features and consequences of conduction in the heart
- action potentials from a single cell eventually propagate throughout the entire heart
- all cells undergo excitation, contract during each beat
- not possible to vary force of heart beat by recruitment
- other mechanisms must be utilized
- stimulating electrodes of pacemakers can be placed on any part of the ventricles
- propagation velocity of action potentials varies greatly in different regions of the heart
- nodal tissue: as slow as 0.05 m/s
- ventricular conducting tissue: as fast as 5.0 m/s
contractility of myocardium
- similarities to skeletal muscle
- mechanoenzyme: actin-activated myosin ATPase
- regulation: Ca2+ release from the sarcoplasmic reticulum, binding to troponin C
- tension: attachment and cycling of myosin cross-bridges between thick, thin filaments
- differences from skeletal muscle
- no mechanical coupling between sarcolemma, sarcoplasmic reticulum (CICR still present)
- increased strength is not gained by motor unit recruitment
- Ca2+ entry into cell, Ca2+ release from the SR, Ca2+ SR reuptake are all regulated
- modulation of contractility typically involves regulation (phosphorylation) of these enzymes
- rates of chemical transitions within cross bridge interaction cycle subject to regulation
- contractility
- contractility: ability of the myocardium to develop tension and to shorten
- involves contractile force, rate of force development, and velocity of shortening
distensibility of myocardium
- distensibility: ability to be lengthened or stretched when a force is applied
- factors contributing to resting distensibility
- titin: protein that spans gap between Z line, ends of thick filaments, and gives passive stretch
- slowly-cycling cross bridges: at rest, some cross bridges still bind actin, and give force when stretched
- stretch influence on subsequent contractions
- number of cross bridges interacting with actin is greater at longer lengths
- amount of Ca2+ released from SR during a sarcolemmal action potential increases
- less physical distance between actin, myosin due to volumetric considerations
- thus length of vetricular cells at onset of each contraction affects force of contraction
refractoriness of myocardium
- refractory: unable to respond to an applied stimulus
- refractoriness in the heart
- begins with depolarization (upstroke), ends when membrane potential has repolarized to 50-90% of resting
- time: typically lasts several hundred milliseconds
- consequences
- refractory period lasts into myocardial relaxation phase, allowing relaxation between beats
- permits filling of the ventricles with blood prior to contraction, allowing more efficient pumping
Origin and Conduction of Cardiac Excitation
- anatomy: structures of cardiac conduction
- atria
- sinoatrial (SA) node
- interatrial and internodal tracts
- atrial muscle
- atrioventricular (AV) node
- ventricles
- Bundle of His
- right and left bundle branches
- terminal arborization (Purkinje tissue)
- ventricular muscle
action potential generation and conduction in normal heart
- conduction
- atrial contraction
- pacemaker: site of origin of the cardiac impulse (generally the SA node)
- conduction: originates in the SA node, spreads to AV node and atrial muscle via interatrial pathways
- contraction: virtually synchronous due to short distances of conduction
- AV node
- conduction: propagates through internodal tracts at a highly reduced velocity
- primarily responsible for delay between atrial, ventricular contractions
- ventricular contraction
- conduction: bundle of His through bundle branches, Purkinje system into terminal arborizations and muscle
- contraction: virtually synchronous (range <>
- conduction velocities
- SA node: 0.05 m/s
- internodal tracts: 1.0 m/s
- atrial muscle: 0.3 m/s
- AV node: 0.05 m/s
- His, Purkinje: 3.0 to 5.0 m/s
- ventricular muscle: 0.3 m/s
determinants of conduction velocity
- cell diameter: conduction velocity varies directly with diameter
- His-Purkinje cells: largest diameter cells in the heart, fastest conduction velocity
- mechanism: increased volume of charge carriers lowers axonal Ri
- factors in conduction velocity
- rate of depolarization during upstroke, depolarization phase of AP
- slow conduction: small upstroke velocities (5 V/s in nodal cells)
- fast conduction: large upstroke velocities (500 V/s in Purkinje cells)
- amplitude of AP overshoot (potential reversal)
- slow conduction: virtually no overshoot
- fast conduction: large overshoot (approaching +35 mV)
automaticity
- sinoatrial node: normal site of the cardiac pacemaker
- pacemaker current: analogous to K+ channels in muscle conduction, but with opposite direction
- designation: If (“funny”)
- activation: only activated at very negative potentials
- deactivation: self limiting; turns off as potential increases
- aspects of membrane potential in a cardiac nodal cell
- diastolic depolarization: slow, progressive depolarization in membrane potential
- occurs during diastole (between contractions) in cells exhibiting automaticity
- other names: phase 4 depolarization, pacemaker potential
- threshold potential: potential at which an action potential is initiated 50% of the time
- action potential: transient, propagating change in membrane potential
- results from regenerative increase in inward currents, subsequent activation of outward currents
- slow: APs in nodal cells depolarize slowly
- maximum diastolic potential: most negative membrane potential during diastole (follows end of AP)
- ion channels in a nodal action potential
- diastolic depolarization: inward Na+ (If)
- action potential: inward Ca2+
- repolarization: outward K+
- mechanisms for changing the automaticity of pacemaker cells
- biochemical methods
- alter rate of diastolic depolarization
- increased diastolic depolarization: increased APs
- decreased diastolic depolarization: decreased APs
- examples: caffeine, emotional stress, exercise
- alter threshold potential
- depolarization of threshold potential: decreased APs
- hyperpolarization of threshold potential: increased APs
- examples: certain antiarrhythmic drugs (INa, ICa blockers)
- alter maximum diastolic potential (MDP)
- depolarization of MDP: increased APs
- hyperpolarization of MDP: decreased APs
- physiological methods of decreasing heart rate
- block If (theoretical)
- increase parasympathetic output (M2 receptor agonists)
- decrease sympathetic output (β-blockers)
localization of automaticity
- describing automatic cardiac cells
- true pacemaker: cells in normal hearts that generate the AP leading to the heart beat (usually SA node)
- latent pacemaker: cardiac cells with the capability of automaticity, other than true pacemaker
- normally do not spontaneously generate AP
- cells with greatest degree of automaticity reach threshold first
- other automatic cells are preemptively excited by propagating APs generated by the true pacemaker
- SA node generally has greatest automaticity, dominating other automatic cells
- ectopic pacemaker: automatic cell outside SA node that generates an AP leading to one or more beats
- includes latent pacemakers that have become true pacemakers
- numerous physiological, pathological processes can cause this to occur
- inherent rates of discharge of automatic cells
- in the absence of extrinsic neural, chemical influences:
- SA node: 120 /min
- internodal tract: 80-100 /min
- AV node: 80-100 /min
- His-Purkinje system: 30-50 /min
- greater numbers of If channels in more automatic cells
- mechanisms for shifting the site of automaticity to ectopic regions
- selectively suppress the automaticity of the SA node
- allows the next most automatic cells (usually AV node) to become the (ectopic) pacemaker
- occurs with aging
- selectively enhance the automaticity of latent pacemaker cells
- cells achieve threshold before SA node, thus becoming the (ectopic) pacemaker
- block conduction between SA node, lower heart (e.g. block the SA node)
- SA node will continue to be the atrial pacemaker
- Purkinje cells, in absence of SA control, become ventricular pacemakers
- this causes asynchrony between contraction of the atria, ventricles
- automaticity vs. conduction velocity: two different characteristics of membrane potential
- automaticity: depends on rate of diastolic depolarization
- conduction velocity: depends on cell diameter, upstroke velocity, overshoot
Ionic Currents Underlying Cardiac Membrane Potentials
description of cardiac action potentials
- diastolic depolarization
- not present in atrial, ventricular myocytes
- in all other tissues, automaticity declines with distance from SA node in normal conduction
- characteristics of specific action potentials
- ventricular myocyte action potential
- fast action potential: high upstroke velocity
- no diastolic depolarization (If): steady potential at rest
- refractoriness absolute: persists for most of the action potential
relative: during last stages of repolarization
- Purkinje action potential
- hybrid of ventricular, nodal action potentials
- undergoes diastolic depolarization, but at a lower rate than nodal cells
- bundle branches: longest action potentials
ionic basis for cardiac Em
- phase 0: upstroke, overshoot of the action potential
- atrial, internodal tract, ventricular, and Purkinje cells
- mechanism: fast Na+ channels
- upon triggering, Na+ channels rapidly open to allow influx of Na+ ions, depolarization
- with depolarization, Na+ channels rapidly inactivate, usually closing before ENa is reached
- K+ channels are used to reestablish polarity
- speed: rapid
- velocity of depolarization: 150 to 500 V/sec
- conduction velocity: 0.3 to 5.0 m/s
- variability in upstroke and conduction: Na+ channel inactivation
- as membrane potential becomes less negative, more Na+ channels are inactivated
- at a resting potential of -100 mV, almost all channels are available (closed, but not inactive)
- at a resting potential of -60 mV, almost all channels are unavailable (inactive)
- action potential overshoot (and thus conduction velocity) depends on initial number of available channels
- initial resting depolarization can therefore significantly slow conduction velocity
- tetrodotoxin: selectively blocks Na+ channels, preventing depolarization
- SA and AV nodal cells
- mechanism: slow L-type Ca2+ channels (DHP receptors)
- channels conduct both Ca2+ and Na+, but predominantly Ca2+
- AP triggering causes influx of Ca2+, while depolarization causes inactivation of channels
- K+ channels are used to reestablish polarity
- speed: slow
- both activation and inactivation of Ca2+ channels is slow, so overshoot and conduction is decreased
- velocity of depolarization: 5-10 V/s; overshoot <>
- note: slow L-type Ca2+ channels are found in all non-nodal cells as well
- Ca2+ current contributes to phase 2 (plateau phase)
- slow incoming Ca2+ current maintains depolarized state
- subsequent inactivation allows repolarizing channels to take over, repolarize myocyte
- L-type Ca2+ can also allow contraction in partially depolarized non-nodal cells
- at -60 mV, Na+ channels are almost all inactive
- cells can still undergo a slow action potential utilizing L-type Ca2+ channels
- in this case, contraction is slow and resembles that of nodal tissue
- phase 1: initial rapid repolarization
- mechanism
- inactivation of the fast Na+ current
- activation of the transient outward K+ current (Ito)
- localization
- Purkinje cells: prominent
- SA, AV cells: absent
- phase 2: plateau of the action potential (distinguishing characteristic of cardiac AP)
- mechanisms
- L-type Ca2+ current: flows for 200 msec or longer, maintaining positive membrane potential
- IK: gradually increasing conductance to K+ during the plateau
- during the plateau, L-type ICa dominates
- phase 3: repolarization to resting potential (or maximum diastolic potential)
- three separate mechanisms
- L-type Ca2+ current: eventually slows due to inactivation
- IK: continued increased membrane permeability to K+
- Na+/K+ ATPase: electrogenic effects
- repolarization brings potential back to its diastolic level
- phase 4: resting potential / diastolic depolarization
- non-automatic cells
- effect: steady diastolic resting potential (about -90 mV)
- mechanism: high permeability to K+ via K1 channel
- K1 channel: only open at very negative Em, maintaining polarity
- NOT the same channel as that mediating repolarization
- automatic cells
- effect: progressive diastolic (phase 4) depolarization, resulting in threshold and spontaneous AP trigger
- three mechanisms
- IK channels: time- and voltage-dependent closure, allowing Em to subsequently depolarize
- If channels: specialized channels that activate near maximum diastolic potential
- similar to potassium channels that cause repolarization, but work in the opposite direction
- direct cause of membrane depolarization
- T-type Ca2+ channels: activate near maximum diastolic potential, allowing inward Ca2+ current
- numerous mechanisms may be a consequence of the number of types of cells that can act as pacemakers
TABLE: Summary of Cardiac Action Potentials
phase | nodal cell | ventricular myocyte | Purkinje cell |
phase 4: diastole
| ↑ If (Na+) ↑ gCa (T-type ICa) ↓ gK (IK) | high gK (IK1) | ↑ If (Na+) ↑ gCa (T-type ICa) ↓ gK (IK) |
phase 0: upstroke
| ↑ gCa (L-type ICa) | ↑ gNa (TTX-sensitive) | ↑ gCa (L-type ICa) |
phase 1: initial repolarization
| --- | ↑ gK (Ito) | ↑ gK (Ito) |
phase 2: plateau
| --- | ↑ gCa (L-type ICa) ↓ gNa (TTX-sensitive) ↑ gK (IK) | ↑ gCa (L-type ICa) ↓ gNa (TTX-sensitive) ↑ gK (IK) |
phase 3: repolarization
| ↑↑ gK (IK) | ↑↑ gK (IK) | ↑↑ gK (IK) |
Electrocardiography
theory of electrocardiography
- electrocardiogram: record of electrical changes within the heart as recorded from body surface
- basis of the EKG
- arises from potential differences between regions of the heart during spread of activation
- during activation of the heart, potentials change in a predictable and reproducible pattern
- uneven distribution of cardiac electrical activity can be detected via skin electrodes as potential difference
- model
- potential = (recording – reference)
- depolarization wave movement towards a recording electrode, away from a reference electrode gives (+) ECG
- electrocardiography as a diagnostic tool
- heart rate, rhythm
- pattern of conduction
- site of origin of the pacemaker
- sequence and time required for conduction through the heart
- diseases
- arrythmias
- conduction abnormalities
- hypertrophy (not always bad)
- ischemia
- necrosis
electrocardiography leads
- EKG leads
- lead: any pair of points on the body surface where electrodes are placed to record the EKG
- reference (–) electrode: serves as the reference for potential difference
- recording (+) electrode: number that is shown relative to the reference
- PD = (+) – (–): potential difference (PD) = recording (+) – reference (–)
- interference
- skin potentials are much less (maximum: 1-2 mV) than what would be measured directly on the heart surface
- EKG is thus susceptible to interference from other electrical fields
- external: shield EKG cables and recording devices
- muscular: hold still to maintain 0 mV baseline
- standard limb leads: depolarization movement in the frontal plane (Einthoven’s triangle)
- lead I: measures left arm (+) from right arm (–) 0º
- lead II: measures left leg (+) from right arm (–) +60º
- lead III: measures left leg (+) from left arm (–) +120º
- augmented limb leads: depolarization movement in the frontal plane (supplemental)
- aVF: measures feet from center +90º
- aVR: measures right arm from center -150º
- aVL: measures left arm from center -30º
- reference: average of the other two limb electrodes (e.g. for aVF, reference is shorted left and right arms)
- precordial leads: depolarization movement in the transverse plane (anterior, posterior heart surfaces)
- V1: between ribs 4 and 5, right side of sternum (right ventricle)
- V2: between ribs 4 and 5, left side of sternum (right ventricle, septum)
- V3: curve inferiorly and laterally towards the side of the chest (septum)
- V4: curve inferiorly and laterally towards the side of the chest (septum, left ventricle)
- V5: curve inferiorly and laterally towards the side of the chest (left ventricle)
- V6: side of the chest (left ventricle)
- reference: sum of all three limb leads (thus reference in middle of back)
- does not visualize posterior aspect of the heart very well
- if a problem is suspected there, leads will be placed on the back instead
vector representations of the spread of activation
- patterns
- moving depolarization wave
- towards lead: positive amplitude
- parallel to lead: maximum amplitude
- perpendicular to lead: zero amplitude
- away from lead: negative amplitude
- moving repolarization wave
- towards lead: negative amplitude
- away from lead: positive amplitude
- tissue mass
- increasing: increased amplitude
- decreasing: decreased amplitude
- resting tissue
- uniform depolarization: zero amplitude
- resting potential: zero amplitude
- vector basis of measurement
- formally, EKGs measure surface charge densities
- informally, most think of it as a current wave (spread of activation, or local circuit current)
- ventricles: depolarization from right to left
- myocardium: depolarization from endocardium to epicardium
repolarization from epicardium to endocardium
(i.e. “there and back”)
- mean QRS vector: spatial sum of all instantaneous vectors
- instantaneous vector: direction of charge density movement at a particular moment
- mean QRS vector in young adults is approximately +60º (60º below horizontal)
- conduction velocity and wave magnitude: inverse proportionality
- faster conduction: smaller wave
- slower conduction: larger wave
clinical EKG recording
- lead I electrocardiogram
- idealized lead I electrocardiogram
- P wave: atrial depolarization (positive)
- QRS complex: ventricular depolarization
- Q wave: septal depolarization (negative; may be absent)
- R wave: primary ventricular depolarization (positive)
- S wave: last part of ventricular depolarization (negative)
- T wave: ventricular repolarization (positive)
- waves
- Q wave: septal depolarization
- left bundle branch has branches that course back into, supply septum
- sum of these vectors makes the negative Q wave (not always present)
- R wave: ventricular depolarization (dominated by left ventricle)
- conduction through walls: endocardial à epicardial
- left ventricle is much larger, as is apex
- thus leftward conduction in left ventricle dominates R wave
- S wave: last component of ventricular depolarization (moving away from lead)
- T wave: ventricular repolarization
- endocardium: low number of K+ channels, and thus longer AP
- epicardium: high number of K+ channels, and thus shorter AP
- repolarization of left ventricle moves rightward, causing an upright T wave
- intervals
- P-R interval: corresponds to conduction time from SA node through AV node
- S-T segment: plateau of ventricular action potential; isopotential
- QRS complex: onset of ventricular depolarization
- Q-T interval: period of ventricular depolarization and repolarization
- long QT syndrome: caused by poor ventricular repolarization
- can be due to defective or blocked K+ channels (or high interstitial K+)
- can be due to defective or blocked Na+ channels
- nomenclature: other leads
- theory
- in all leads, Q, R, and S waves are assigned based on polarity and sequence
- in leads other than lead I, QRS waves do not necessarily correspond to identical electrical events
- naming
- Q wave: a negative wave preceding an R wave (sometimes absent)
- R wave: first positive wave in the QRS complex reporting ventricular depolarization
- lead I: reports ventricular depolarization
- V1: reports septal depolarization, which generally moves towards V1
- S wave: negative wave following an R wave
- lead I: final stages of ventricular depolarization
- V1: main phase of ventricular depolarization (moves to the left, away from V1)
reading an ECG
- protocol
- scan the ECG for technical adequacy (noise, signal size)
- measure heart rate, intervals, amplitudes, axis
- identify the rhythm (sinus, supraventricular, ventricular)
- describe abnormalities
- interpret the ECG, listing each abnormality
- compare with previous ECG, if available
- simple estimation of heart rate
- ECG paper
- minor divisions: 40 ms
- major divisions: 200 ms
- estimation
- QRS complex every major division: 300 /min
- QRS complex every two major divisions: 150 /min
- QRS complex every three major divisions: 100 /min
- QRS complex every four major divisions: 75 /min
- QRS complex every five major divisions: 60 /min
- QRS complex every six major divisions: 50 /min
- calculation of the QRS axis
- QRS axis: calculated variable that estimates net direction of depolarization of ventricles
- summation of all vectors generated during ventricular depolarization
- left ventricle is generally the largest tissue mass in normal hearts, so QRS axis usually points in that way
- calculation
- select two leads (typically I and aVF, since their horizontal/vertical direction is easiest for calculation)
- from isopotential, measure amplitudes of Q, R, and S waves
- subtract largest of Q or S wave from R wave
- plot vectors away from center
- direction: based on direction of the lead
- amplitude: based on calculation
- draw lines perpendicular to the end of each vector
- QRS axis: vector from center to the point where perpendicular lines intersect
- normal values: -20º to +110º
- less than -20º left-shifted pregnant, overweight: heart oriented more horizontally
LV hypertrophy: greater depolarization towards the left
- greater than +110º right-shifted thin: heart oriented more vertically
RV hypertrophy: greater depolarization towards the right
- note: angles are relative to lead I, with a positive value corresponding to the direction of right shifting
normal and abnormal 12-lead ECGs
- normal
- sinus rhythm
- rhythm of the heart driven by the sinoatrial node
- marked as regular appearance of a P wave at a constant interval before each QRS complex
- normal
- regular sinus rhythm of 60-100 bpm
- no evidence of pathological processes
- abnormal
- tachycardia: heart rate greater than 100 bpm
- bradycardia: heart rate less than 50 bpm
- atrial fibrillation
- arrhythmia with asynchronous APs arising from multiple ectopic foci in the atria
- seen as irregular baseline, absence of P waves, irregular ventricular rhythm due to irregular AV conduction
- ventricular rhythm
- rhythm of the heart beat driven by an ectopic pacemaker of ventricular origin
- seen as dissociation of P-waves and QRS complexes, and widened QRS complexes
- normal QRS width: less than 120 ms (3 boxes)
- ventricular fibrillation
- arrhythmia with asynchronous APs arising from multiple ectopic foci in the ventricles
- seen as continuous series of up/down deflections of variable amplitude and duration
- left ventricular hypertrophy
- enlargement of the left ventricle, either physiological (athlete) or pathological (hypertensive)
- seen as abnormally large QRS complexes in right or left ventricular leads
- left bundle branch block (LBBB)
- slowed conduction into the left ventricle
- seen as prolonged QRS complex, large R’ waves in left-side leads (I, V5, V6)
- R’ wave: second positive deflection (rabbit ear) caused by sequential ventricular depolarization; can be subtle
- right bundle branch block (RBBB)
- slowed conduction into the right ventricle
- seen as prolonged QRS complex, large R’ waves in right side leads (V1, V2) and/or broad left side S waves
The Heart as a Pump
cardiac valves
- atrioventricular valves: connected to papillary muscles by chordae tendinae
- tricuspid valve: divides right ventricle from right atrium
- bicuspid valve (mitral): divides left ventricle from left atrium
- semilunar valves: each has three cusps
- pulmonic valve: divides pulmonary artery from right ventricle
- aortic valve: divides aorta from left ventricle
- other structures
- sinuses of Valsava: bulges or spaces in arterial walls directly behind valve cusps
- ostia of coronary arteries: within sinus of Valsava in the aorta
- memory device: “ten pin bowling alley” (tricuspid, pulmonic, bicuspid, aortic)
- function: open or close depending on pressure gradient
- valves
- AV valves: close when ventricular pressure is greater than atrial pressure (supported by chordae tendinae)
- semilunar valves: close when arterial pressure is higher than ventricular pressure
- closure
- approximation (coaption): closure of the valve cusps
- insufficiency: failure of valves to fully close
cardiac cycle
- cycle
- ventricular systole: marked by closure of mitral valve, onset of isovolumic contraction
- isovolumetric contraction: ventricle builds tension/pressure, but does not exceed arterial pressure
- ventricular ejection
- rapid ejection: pressure rises to peak, volume drops rapidly
- reduced ejection: pressure falls from peak, volume drops slowly
- ventricular diastole: marked by closure of aortic valve
- isovolumetric relaxation: ventricle loses tension/pressure, aortic valve closes; dichrotic notch
- ventricular filling
- rapid filling: mitral valve reopens, blood rapidly enters ventricles due to atrial buildup (75-80% of filling)
- reduced filling: blood enters more slowly (15-20% of filling)
- atrial systole: contraction causing remaining filling of ventricular volume
- concepts
- dichrotic notch: transient increase in aortic pressure caused by backflow, rebound of blood off valve
- blood pressure
- diastolic: pressure at which aortic valve opens (between isovolumetric, rapid ejection)
- systolic: marked by peak of atrial pressure (between rapid, reduced ejection)
- volume
- end-systolic volume: residual ventricular volume (during isovolumetric relaxation)
- end-diastolic volume: peak of ventricular volume (during isovolumetric contraction)
- directly determines length of individual muscle fibers
- indirectly determines force muscle fibers will develop during subsequent contraction
- filling
- increasing heart rate causes proportional decrease in length of diastole, NOT in filling volume
- rapid filling early in diastole allows filling to remain steady even with increasing heart rate
- only beyond ~180 bpm does rapid filling phase decrease sufficiently to reduce filling volume
- during filling, ventricular pressures are generally less than pressures in great vessels
determinants of ventricular filling
- rate of venous return: greater return à greater filling (aided by ventricular relaxation)
- filling time: greater diastole à greater end-volume
- ventricular distensibility: greater distensibility (compliance) à greater end-volume
- stiff ventricles (e.g. hypertrophy) impairs filling, requiring greater venous pressure
- as ventricular distensibility decreases, atrial contraction becomes a more important contributor
atrial function
- reservoirs: store blood during period that AV valves are closed
- ventricular filling: increasingly important with:
- faster heart rates
- vascular stenosis
- hypertrophied ventricles (decreased distensibility)
- AV valve closure: aid by creating eddy currents that move cusps closer to center of AV orifice
- changes in left atrial pressure during cardiac cycle
- a wave: increasing pressure due to atrial systole
- c wave: transient increase in pressure during isovolumetric contraction (bulging AV valves)
- x descent: results from early ventricular ejection
- during ejection, base of ventricle moves down toward apex
- AV valve, atrium pulled downward, enlarging atrium and reducing pressure
- v wave: increasing pressure due to accumulation of blood within the atrium
- y descent: results from rapid ventricular filling, suction from ventricular relaxation
- left atrial pressure
- contraction: a wave
- ventricular filling/release: c wave, x descent
- atrial filling/release: v wave, y descent
characteristics of ejection
- stroke volume: amount of blood ejected into aorta during a beat
- average: 60-70 mL (60-70% of blood contained within ventricle)
- determinants: primarily force, velocity of ventricular muscle contraction
- end-systolic volume: residual volume contained within ventricle
- ejection fraction: measure of cardiac performance
- corrects for effect of body size on stroke volume
- formula:
- EDV: end-diastolic volume of the ventricle (maximum volume)
- ESV: end-systolic volume of the ventricle (minimum volume)
- SV: stroke volume (difference)
Regulation of Cardiac Function
key concepts
- preload: extent of diastolic filling (i.e. pre-loading of the ventricle)
- generally, as preload increases, stroke volume increases
- measured as EDV or EDP
- afterload: load (or pressure) against which the heart must work
- generally, as afterload increases, stroke volume decreases
- indicators of afterload
- mean arterial blood pressure
- ventricular wall stress (best indicator)
- regulation
- targets
- heart rate (beats / min)
- stroke volume (mL ejected / beat)
- cardiac output (CO): product of heart rate and stroke volume
- mechanisms
- intrinsic: exist within the heart, and do not involve neural control or circulation
- neural: nerve inputs to the heart
- types: parasympathetic, sympathetic
- targets: heart rate, force, and velocity of muscle contraction
- chemical: naturally-circulating or pharmacologic agents that bind receptors, interact with ion pumps
- heteromeric autoregulation
- changes in muscle length (ventricular volume) alter force of muscular contraction (ventricular pressure)
- mechanism: Frank-Starling mechanism
the Frank-Starling mechanism
- experiment
- design
- canine heart-lung preparation isolated from chemical, neural effects
- effects on cardiac performance studied with varying factors
- findings
- increased ventricular filling
- led to increased contractile force, stroke volume
- extra blood quickly pumped out in subsequent beats
- increased aortic pressure
- less blood pumped into the aorta during the first few transitional beats
- led to increased residual volume of the ventricles, stretched ventricular myocytes
- led to increased contractile force, returning stroke volume to normal
- cardiac performance
- ventricular function vs. chamber dimensions
- y: stroke volume, cardiac output, or stroke work
- x: venous pressure, atrial pressure, or ventricular end-diastolic pressure (VEDP)
- VEDP / VEDV: inputs
- preload: amount of blood and pressure present within the ventricles at the end of diastole
- afterload: pressure against which the heart works
- systemic arterial pressure: good indicator of afterload
- wall stress: best indicator of afterload
- wall stress as the best indicator of afterload
- LaPlace’s Law for spherical wall stress:
- P: ventricular pressure
- r: chamber radius
- t: wall thickness
- situations where mean arterial blood pressure (MABP) is a poor indicator
- aortic stenosis
- problem: narrowing of the aortic valve opening
- left ventricle must generate blood pressure far in excess of systemic pressure
- dilated cardiomyopathies
- problem: chamber radius is increased, wall thickness decreased relative to normal
- wall stress substantially greater than normal to maintain adequate arterial blood pressure
the basis for the Frank Starling relationship
- alteration in thick/thin filament overlap (minor)
- end-diastolic sarcomere lengths range from 1.8 to 2.3 μm
- below 1.8 μm, there is virtually no tension
- within plateau of length-tension relationship, substantial decreases in tension
- implication: most of variation must involve other mechanisms
- L-type channel-dependent release of Ca2+
- amount of Ca2+ released into myoplasm during EC coupling depends on length
- increased length (distension) leads to increased Ca2+ release, possibly due to:
- increased L-type current, Ca2+ entry into the cell
- increased sensitivity of the SR to the trigger Ca2+ entering the cell
- implication: increased stretch leads to increased Ca2+ and contractility
- alteration in probability of cross bridge binding (most important)
- constant volume system: in striated muscles, as cylinder length increases, diameter decreases
- increased distension leads to smaller distance between actin and myosin, increased rate constant for binding
- implication: increased stretch leads to greater probability of cross bridge formation
implications of the Frank Starling relationship
- systemic venous blood pressure is kept from rising to high levels
- output of the two ventricles is self-correcting
- stroke volume is normal in individuals with chronic hypertension
- work: work = P · ΔV
= mean arterial blood pressure · stroke volume
= MABP · SV
- acute hypertension
- under normal circumstances, MABP is well regulated and relatively constant
- with sudden hypertension, MABP increases, and work is initially constant, so SV decreases
- decreased SV à increased ESV à increased EDV à increased work capacity of the heart
- end result: increased work, increased MABP, normal stroke volume (metabolic burden)
- problem: hypertrophy can occur over time, ultimately leading to heart failure
Neural Regulatory Mechanisms
anatomy of autonomic innervation
- parasympathetic
- preganglionic
- cell bodies: medulla
- axons: project to peripheral ganglia via the vagus (X) verve
- neurotransmitter: acetylcholine
- postganglionic
- cell bodies: peripheral ganglia near or in the heart
- axons: project to targets
- targets: SA node, internodal tracts, atrial muscle, AV node
- ventricles receive virtually no input from parasympathetic nerves
- neurotransmitter: acetylcholine
- receptor: muscarinic (M2)
- function: slows heart rate, conduction velocity
- cardio-inhibitory center (CIC): cell bodies of the preganglionic parasympathetic neurons
- diffuse bilateral center in the medulla
- tends to dominate at rest
- sympathetic
- preganglionic
- cell bodies: lateral horns of the spinal cord, T1 to T6
- axons: synapse in paravertebral chains
- neurotransmitter: acetylcholine
- postganglionic
- cell bodies: paravertebral chains
- axons: project to the heart via the superior, middle, and inferior nerves
- targets: all structures of the heart, including the ventricles
- neurotransmitter: norepinephrine
- receptor: adrenergic (β1)
- cardio-accelerator center (CAC): neuronal control of preganglionic sympathetics
- diffuse bilateral center in the brainstem
- synapse on lateral horn cells
functions of the heart regulated by autonomic nerves
- heart rate
- chronotropism: change in the rate of the heart beat
- positive chronotropism: increased heart rate
- negative chronotropism: decreased heart rate
- mechanism: changes in the rate of diastolic depolarization
- conduction of excitation
- dromotropism: induced changes in action potential conduction velocity
- AV node: functionally most important in controlling conduction velocity
- anything arising from SA node must traverse AV node to control ventricular excitation
- mechanism: changes in the intensity of the depolarizing current (Na+ or Ca2+)
- alters upstroke velocity of the action potential
- alters overshoot of the action potential
- contraction force and velocity
- inotropism: induced changes in myocardial contractile force, resulting in altered stroke volume
- positive inotropy: increase in developed force (or pressure)
- negative inotropy: decrease in developed force (or pressure)
- mechanisms
- change in magnitude of slow Ca2+ current
- modulation of Ca2+ release
- modulation of Ca2+ binding
- modulation of metabolic energy balance
- excitability or irritability
- excitability
- laboratory definition: tendency of the tissue to respond to a stimulus
- clinical definition: tendency of the heart to develop arrythmias
- as such, excitability is often also referred to as irritability
cardiac actions of the parasympathetic nerves
- decreases heart rate
- mechanism: influences diastolic depolarization (phase 0) ionic currents via ACh binding to M2 receptors
- increases membrane K+ conductance (gK), slowing rate of membrane depolarization
- reduces intensity of Na+ current through If channels
- blocks T-type Ca2+ current
- selective effect: targets only atrial walls, AV node
- decreases conduction velocity through AV node
- mechanism
- ACh reduces magnitude of L-type Ca2+ current
- causes decrease in upstroke velocity, overshoot, and thus conduction velocity
- effect: longer time for excitation to traverse AV node, longer P-R interval
- note: can sometimes increase conduction velocity along atrial muscle cells
- ACh-induced increase in membrane gK hyperpolarizes resting membrane potential (-90 to -100 mV)
- increases number of available fast Na+ channels, ultimately increasing conduction velocity
- decreases contractility of atrial muscle cells
- mechanism: decreased amplitude of L-type Ca2+ current (required to initiate Ca2+ release from SR)
- result: negative inotropy, decrease in atrial kick
- selective effects: parasympathetics target atrial walls and AV node, but do not work well in ventricles
- significantly fewer muscarinic receptors in Purkinje cells, ventricular muscle
- significantly less innervation of ventricular cells
cardiac actions of sympathetic nerves
- increases heart rate
- mechanism: influences ionic currents via norepinephrine binding to β1 receptors (PKA-mediated)
- accelerated rate of gK decrease
- increased inward movement of Na+ through If channels
- increased inward Ca2+ channel current through T-type channels
- broad effect: all latent pacemakers receive sympathetic innervation, all have β1 receptors
- increases conduction velocity through AV node
- nodal cells: increase in rate of rise and amount of L-type Ca2+ current
- causes significant increase in AV upstroke, overshoot, and thus conduction velocity
- effect: shorter time for excitation to traverse AV node, shorter P-R interval
- non-nodal cells: mechanism is unclear; may involve hyperpolarization of the threshold potential
- increases contractility of muscle cells
- positive inotropy
- mechanism: upregulation of adenylate cyclase, consequent increase in active PKA
- increase in magnitude, duration of slow L-type Ca2+ current; consequent increase in [Ca2+]i
- increased Ca2+ release from intracellular stores
- increased rate of cross-bridge cycling
- result: increase in atrial kick, and consequent increase in ventricular stroke volume
- increased rate of relaxation
- mechanism: myofibrillar protein phosphorylations (primarily TnI subunit)
- increased rate of cross bridge cycling (length of rate-limiting steps is reduced)
- increased Ca2+ reuptake by SR
- mediated by phosphorylation of phospholamban
- phospholamban: accessory protein to the SR Ca2+ pump
- result: increase in rate of relaxation
- net effect: increase amplitude, reduce duration of cardiac twitch
- increases excitability of cardiac tissue
- mechanism: unclear
- threshold closer to max diastolic potential
- automaticity of latent pacemakers is increased
- problem: hearts subjected to excessive sympathetic innervation tend to develop arrythmias
levels of cardiac autonomic nerve activity in normal humans at rest
- SA node automaticity: 120 beats/minute in absence of outside influence
- normal resting heart rate: 60-80 beats/min
- implication: at rest, heart has a generally parasympathetic tone
TABLE: Summary of Cardiac Effects of Autonomic Nervous System
| parasympathetics | sympathetics |
target | atria | atria, ventricles |
mechanism | anti-β effects (↓ PKA) | ↑ PKA (protein, channel phosphorylation) |
chronotropy (heart rate) | decrease (negative chronotropy) ↑ gK ↑ If ↑ ICa | increase (positive chronotropy) accelerated reduction in gK ↓ If ↓ ICa |
dromotropy (conduction velocity) | decrease (through AV node) ↓ L-type ICa | increase (through AV node) ↑ L-type ICa |
inotropy (force, speed) | decrease (negative inotropy) ↓ L-type ICa | increase (positive inotropy) ↑ L-type ICa ↑ SR Ca2+ release ↑ SR Ca2+ reuptake speed ↑ cross bridge kinetics |
excitability (irritability) | decrease ↑ gK | increase mechanism unclear: threshold closer to max diastolic potential, automaticity of latent pacemakers is increased |
Hemodynamics
- hemodynamics: study of the physical factors that produce and affect blood flow
- based on idealized laws developed to quantify flow of liquid through tubes
- quantitatively apply only when liquid is Newtonian in nature (ideal)
- nevertheless, can aid in illustrating general properties on which blood flow is based
physical properties of flow
- pressure
- pressure is form of energy that causes liquid to flow
- flow occurs when pressure exceeds resistance
- resistance is presented by the tube, inertia of the liquid
- pressure can be converted to other forms of energy
- kinetic energy: energy of flow
- heat: byproduct of overcoming resistance to flow
- pressure energy in a tube is a sum of lateral and end pressure
- energy:
- lateral pressure: pressure exerted on the walls of the container (potential energy)
- end pressure: pressure exerted by energy of flow (kinetic energy)
- note that measurement of flow is measurement of total energy, not just of kinetic energy
- resistance
- determinants
- length of tube: resistance is proportional to tube length
- radius of tube: resistance is inversely exponentially proportional to tube radius
- fluid viscosity: resistance is inversely proportional to viscosity
- measurement
- resistance:
- L: tube length
- r: tube radius
- η: fluid viscosity
- even a small change in radius will profoundly alter resistance (R is proportional to 1/r4)
- flow
- Poiseluille’s law:
- Q: flow
- ΔP: pressure gradient
- implications
- flow is directly proportional to size of the pressure gradient and radius of the vessel
- flow is inversely proportional to length of the vessel and viscosity of the fluid
practical applications
- driving force of flow: systemic arterial blood pressure
- physical properties of the vasculature
- parallel arrangement: vascular beds of systemic circulation are arranged in parallel
- pressure in arteries supplying each bed is nearly the same
- same driving force for flow exists at entrance to each bed
- consequently, increased pressure is not efficient in selective flow
- resistance: flow through each vascular bed is primarily determined by net radius of the vessels
- resistance to flow depends on the radius of the vessels
- radius of vessels is primarily determined by contraction/relaxation of circular smooth muscles
- several mechanisms exist to control this
- arterioles: narrow, high resistance vessels located at the end of the arterial tree
- divides systemic circuit into a high pressure region and a low pressure region
- effect: decreases velocity of flow
- increases upstream pressure, decreases downstream pressure
- end result is to increase pressure gradient across the constricted region
vascular resistance
- resistance:
- ΔP: mean arterial blood pressure (MABP) - RA pressure
- RA pressure is generally close to zero
- ΔP is thus approximated as MABP
- Q: flow
- total peripheral resistance (TPR)
- theory
- ΔP: approximated as MABP, since RA pressure is typically close to 0
- TPR is the primary determinant of MABP
- Q can be thought of as cardiac output (CO)
- equation:
- MABP: mean arterial blood pressure
- CO: cardiac output
- TPR is less than the largest of the individual resistances
- consequence of parallel arrangement of vascular beds
- resistance in series:
velocity of flow
- velocity: length of a column of blood passing a point in the circuit per unit time
- velocity is inversely proportional to cross-sectional area of the vessel
- thus as vessel gets bigger, velocity (and kinetic energy) decrease
- implications
- velocity is rapid in arteries and veins, but slow in capillaries
- allows time for exchange of materials across the capillary wall
Bernoulli’s principle
- Bernoulli’s principle: total energy (E = PE + KE) at any point in a system must remain constant
- sum of lateral pressure (PE) and end pressure (KE) must remain constant
- implication: areas of decreased flow receive additional lateral pressure
- arterial aneurism
- bulging of vessel causes reduction in flow and increase in lateral pressure
- as such, aneurisms tend to be unstable and progressive
patterns of blood flow within vessels
- patterns of flow
- streamlined (laminar) flow
- liquid is layered as it flows, and flow occurs without intermixing of the fluid
- each layer (lamella) moves at a different velocity, with greatest velocity at the center
- pattern: ordered, structured, efficient, and quiet
- turbulent flow
- liquid rolls, mixes together as it flows
- pattern: less efficient, requires higher pressure, and is audible
- describing turbulence
- Reynold’s number:
- v: velocity of flow
- D: diameter of tube
- d: density of liquid
- η: viscosity of liquid
- as Re increases, likelihood of turbulence in flow also increases
- with all else constant, faster flow à increased turbulence
- clinical applications
- abnormal constrictions of dilations of vessels can cause audible downstream turbulence (brutis)
- anemia reduces viscosity of blood, which can result in turbulence
- sphygmomanometry relies on turbulent flow sounds in vessels constricted with a pressure cuff
heart sounds and murmurs
- listening to heart sounds
- stethoscope: that amplifying thingy
- ascultation: the technique of listening for sounds anywhere in circulation
- normal heart sound
- S1: AV valve closure onset of systole “lub”
- S2: SL valve closure onset of diastole “dub”
- heart murmur
- terms
- valvular insufficiency: condition in which blood is able to regurgitate backward through a closed valve
- valvular stenosis: condition in which a valve does not open sufficiently during movement of blood
- findings
- systolic murmur from AV valve: insufficiency (systole: AV valve closes)
- systolic murmur from SL valve: stenosis
- diastolic murmur from AV valve: stenosis (diastole: SL valve closes)
- diastolic murmur from SL valve: insufficiency
LaPlace’s law for wall tension in blood vessels
- LaPlace’s law: T = P · r
- P: intraluminal pressure
- r: radius of vessel
- implications
- pressure is smaller, and radius is far smaller in capillaries than arteries
- as such, the tension is significantly lower, allowing capillary walls to be much thinner
Regulation of Contraction of Vascular Smooth Muscle
- functions of contraction in the cardiovascular system
- reduce the radius of the vessel
- contraction increases resistance to blood flow through the vessel
- arterioles: most important, as they determine TPR
- reduce the capacity of the vessel
- contraction decreases diameter of the lumen, decreasing vessel capacity
- systemic veins: most important, as a reduction in venous capacity causes more blood return to the heart
- increases cardiac output
- increases arterial blood pressure
- reduce the distensibility of the vessel
vascular resistance
- peripheral resistance
- resistance to flow is almost entirely within peripheral vessels, as opposed to the heart
- calculation: depends on pressure gradient (ΔP), flow (Q) across a bed
- total peripheral resistance
- systemic vascular beds arranged in parallel
- inverse of TPR is the sum of the inverses of all vascular beds
- consequence: TPR is less than the resistance of any single vascular bed
- arteriolar smooth muscle: major determinant of TPR
- arterioles
- located at entrance to each capillary
- ideally positioned to control capillary blood flow
- capillaries
- precapillary sphincter: smooth muscle located at the entrance of the capillary
- determines actual blood flow through individual capillary
terms applied to change in vessel radius
- vasoconstriction: decrease in radius of a blood vessel
- types
- passive: recoil due to fall in intraluminal pressure
- active: contraction of smooth muscle in the vessel wall
- contractile factors
- activity in sympathetic adrenergic nerves (primary importance in controlling TPR, capacity, and MABP)
- hormones and neurotransmitters
- exogenous therapeutic agents
- vasodilation: increase in radius of a blood vessel
- types
- passive: stretch due to increase in intraluminal pressure
- active: relaxation of smooth muscle in the vessel wall
- contractile factors
- inhibition of sympathetic adrenergic nerves (important for controlling TPR and MABP)
- therapeutic agents
- local chemical changes produced by tissue metabolism or vascular endothelium
innervation of vascular smooth muscle
- distribution
- all vascular beds receive sympathetic adrenergic innervation
- anatomy
- preganglionic sympathetic: lateral horn of the spinal cord
- postganglionic sympathetic: paravertebral chain
- density of innervation is significantly reduced in:
- brain
- coronary arteries
- pulmonary circulation (determined primarily by local [O2], [CO2])
- sympathetic vasoconstriction: α1 receptors
- vasomotor center: bilateral controller of sympathetic innervation
- located in the medulla
- controls preganglionic sympathetic constrictor neurons in thoracic, lumbar segments (T1-L2)
- sympathetic innervation of smooth muscle contraction
- neurotransmitter: norepinephrine
- receptors: α1 receptors on vascular smooth muscle cells
- distribution
- skin
- skeletal muscle
- bone
- abdominal and pelvic regions (splanchnic vascular beds)
- effect: actively controls TPR and venous capacity
- a tonically-active (3-5 Hz) single set of nerves regulates TPR over a broad range
- increase or decrease of this firing frequency causes resultant changes in TPR, MABP
- sympathetic vasodilation: β2 receptors
- sympathetic innervation of smooth muscle contraction
- neurotransmitter: norepinephrine
- receptors: β2 receptors on vascular smooth muscle cells
- distribution: skeletal muscle beds
- effect: offsets vasoconstriction due to sympathetic adrenergic neurons, to some degree
- beneficial effects in facilitating blood flow to skeletal muscle during exercise
- overall, local [metabolite] dominates, and β2 receptors don’t play that much of a role
regulation of vascular smooth muscle contraction
- local metabolites
- vasodilatory factors
- decreased PO2
- increased PCO2
- decreased pH
- increased adenosine
- increased extracellular [K+]
- increased osmolarity
- increased temperature
- advantage: localized response
- metabolism stimulates changes, leading to increased blood flow on an “as needed” basis
- highly efficient at increasing blood flow to a specific organ or vascular bed
- endothelial cells
- endothelium: single layer of cells lining or comprising the luminal wall of blood vessels
- functions
- formation of a diffusion barrier between circulation and surrounding fluid compartments
- formation of a smooth surface for interaction with blood cells
- modulation and synthesis of numerous blood-borne substances
- modulation or control of contractile state of smooth muscle
- examples
- nitric oxide (NO)
- synthesis and release induced by shear stress across the endothelial surface (mechanism unknown)
- effect: localized vasodilation (reduces velocity of flow, prevents further injury)
- acetylcholine (ACh)
- binds muscarinic receptors on endothelial cells, inducing synthesis and release of NO
- effect: localized vasodilation
- function: unknown
- ACh does not circulate in the blood
- few vessels receive cholinergic innervation
- use as a diagnostic tool
- normal tissues: vasodilate in response to ACh due to interaction with endothelium
- damaged tissues: constrict in response to ACh due to loss of endothelium, interaction with smooth muscle
- other substances
- vasodilation: response to histamine, bradykinin
- vasocontstriction: response to arachidonic acid, stretch
- monoamine oxidase: endothelial enzyme that inactivates norepinephrine and serotonin
- platelet aggregation, blood coagulation: induced by numerous factors released by the endothelium
- myogenic response
- stretch reflex
- effect: contraction in response to simple stretch
- function: allows greater precision in control of flow to a vascular bed
- increasing stimuli for vasodilation (metabolites, pressure) are counteracted by stretch reflex
- at high stimulus intensity, stretch reflex becomes less effective
- mechanism: stretch activation of membrane Ca2+ channels
- inward current depolarizes cell, induces contraction
- self-limiting: stretch-induced contraction reduces cell length, thereby reducing conductance of Ca2+ channels
- atrial natriuretic factor (ANF)
- released by atrial, ventricular myocytes in response to increased EDV
- targets: kidney, adrenal glands, certain regions of the brain
- effects: reduce blood pressure
- diuresis (increased urine output)
- natriuresis (increased Na+ content of the urine)
- vasodilation
- renin-angiotensin-aldosterone system
- pathway: formation of angiotensin II
- renin is secreted in response to:
- reflex activation of sympathetic outflow to the justaglomerular apparatus
- direct release from renal afferent arterioles in response to low blood pressure
- renin catalyzes cleavage of circulating angiotensinogen into angiotensin I
- angiotensin-converting enzyme (ACE) catalyzes cleavage of angiotensin I into angiotensin II
- ACE found primarily in endothelial surfaces of lung vasculature
- angiotensin II: effects to increase blood pressure
- vasoconstrictor
- stimulates Na+ absorption, thereby increasing water retention
- stimulates aldosterone release from the adrenal cortex, which increases Na+ reabsorption by the kidney
- stimulates hypothalamic centers to increase thirst
autoregulation
- autoregulation: maintenance of constant flow regardless of perfusion pressure
- with elevated pressure, flow decreases back to normal due to vasoconstriction
- with reduced pressure, flow increases to normal due to vasodilation
- mechanisms
- myogenic response: appropriate activation of the stretch reflex
- increased local metabolites: appropriate synthesis of metabolites to restore flow rate
reactive hyperemia
- reactive hyperemia: greater than normal volume of blood flow following a period of zero blood flow
- mechanism: abundance of vasodilating agents
- during zero flow, changes in pH, PO2, PCO2, and other metabolites favor vasodilation
- upon restoration, flow is initially greater than normal but recovers once metabolites are cleared
- longer occlusion à longer hyperemia
Neural Regulation of Mean Arterial Blood Pressure
determinants of MABP
- amount of blood in arteries: depends on amount entering vs. amount leaving arterial tree
- CO: cardiac output amount of blood entering arterial tree
- TPR: total peripheral resistance determines blood leaving arterial tree
- cardiac output: depends on heart rate and stroke volume
- HR: heart rate
- SV: stroke volume
- influences on variables in maintaining constant MABP
- cardio-inhibitory center (CI): heart rate and stroke volume (CO)
- cardio-accelerator center (CA): heart rate and stroke volume (CO)
- vasoconstrictor center (VC): total peripheral resistance (TPR)
mechanisms influencing activity of CI, CA, and VC centers
- neural influences from higher centers in the brain
- centers in the cortex, hypothalamus:
- alter output of impulses from CI, CA, and VC centers
- emotional states
- activate centers in the brainstem (CI, CA, VC)
- effect the release of epinephrine from the adrenal glands
- body temperature control centers in the hypothalamus
- influence pool of VC neurons responsible for control of blood flow to the skin
- local chemical effects within the brain
- effects of PCO2
- VC center: highly sensitive to cerebral PCO2 (interstitial fluid)
- 45 mmHg: normal PCO2
- increased PCO2: increase in VC activity effecting vasoconstriction, increase in TPR
- decreased PCO2: decrease in VC activity allowing vasodilation, decrease in TPR
- mechanism
- direct effects on centers due to changes in [H+]
- note: vasoconstriction does not affect brain and heart due to reduced sympathetic innervation
- Cushing’s phenomenon: compensatory increase in MABP in response to increase in brain CO2
- during trauma, blood flow to the brain decreases, CO2 is not cleared as fast, and PCO2 increases
- VC center stimulated, causing systemic vasoconstriction and restoring blood flow to the brain
- note: vascular beds of brain, heart do NOT participate in generalized vasoconstriction (less innervation)
- voluntary hyperventilation
- causes decreased PCO2, effecting a reduced tone in the VC center
- TPR falls, venous capacity increases, and MABP falls
- if MABP falls too much, there is inadequate cerebral blood flow and unconsciousness may result
- CI, CA centers
- increased cerebral PCO2: stimulates both the CA and CI centers
- CI typically dominates, and counterintuitively, HR decreases
- mechanism: direct effects on centers due to changes in [H+]
- effects of PO2
- within brain: small ΔPO2 has little effect; large reductions can cause depressed neural activity
- outside brain: other mechanisms exist by which altered PO2 can stimulate CV system
reflex effects from peripheral neural receptors: arterial baroreceptors
- location and innervation
- carotid sinus baroreceptors: glossopharyngeal (CN IX) nerve
- aortic arch baroreceptors: vagus (CN X) nerve
- mechanism: stretch receptors embedded in vessel walls
- magnitude: effects depend on frequency, duration, and number of active receptors
- tonic activation: some activated during each beat of the cardiac cycle
- frequency: increased discharge, duration with increasing MABP
- recruitment: increased numbers activated with increased MABP
- tonic effects of baroreceptors
- stimulate the CI center
- CI center is tonically active due to constant stimulation by baroreceptors
- inherent SA discharge: 120 beats/min
- normal resting discharge: 60-80 beats/min
- modifying activation
- increasing MABP: increased stimulation, decreased heart rate
- decreasing MABP: decreased stimulation, increased heart rate
- inhibit CA center
- CA center is minimally active due to tonic inhibition by baroreceptors
- modifying activation
- increasing MABP: increased inhibition, decreased heart rate/contraction force
- decreasing MABP: decreased inhibition, increased heart rate/contraction force
- inhibit VC center
- VC center is tonically active, but less than normal due to constant inhibition by baroreceptors
- inherent discharge (normal PCO2) frequency = 10 Hz
- resting discharge rate: frequency = 3-5 Hz
- modifying activation
- increasing MABP: increased inhibition, decreased sympathetic vasoconstriction (vasodilation)
- decreasing MABP: decreased inhibition, increased sympathetic vasoconstriction
TABLE: Summary of Tonic Effects of Baroreceptors
activity | method | action | effect |
stimulate CIC | ↓ HR | ↓ CO |
↓ MABP |
inhibit CAC | ↓ HR, SV | ↓ CO | |
inhibit VC | vasodilation | ↓ TPR, ↓ CO |
- “buffer” reflexes
- baroreceptors cannot completely prevent any change in arterial pressure
- instead, they provide fast, effective, moment-to-moment regulation of MABP
- with prolonged abnormality, reflexes do adapt to a new standard
- hemorrage: loss of blood directly from the cardiovascular system
- hemorrhage causes a fall in arterial pressure:
- direct loss from the arterial tree
- reduction in blood return to the heart
- response: decreased activity of baroreceptors leading to increased MABP
- CI no longer stimulated, resulting in increased heart rate
- CA no longer inhibited, resulting in increased heart rate and force of contraction
- VC no longer inhibited, resulting in constricted vessels and increased TPR
- function
- mild hemorrhage (<30%>
- severe hemorrhage: prolongs survival time of the organism
- value
- heart is able to pump all blood it receives
- blood is diverted to the brain and heart, which most need blood
- injection of a direct vasoconstrictor drug
- injection of a vasoconstrictor causes constriction of vessels leading to increased TPR, increased MABP
- response: activation of baroreceptors
- CI center activated above normal, slowing heart rate
- CA center further inhibited, reducing heart rate and contraction strength
- VC center further inhibited, reducing constriction and lowering CO
- effect: pharmacologic increase in MABP is moderated
effects on MABP due to stimulation of peripheral chemoreceptors
- structures
- carotid bodies: bilateral structures located at the bifurcation of the common carotid arteries
- aortic bodies: located near the aortic arch
- innervation: glossopharyngeal, vagus nerve
- synapse on CV control centers (especially VC center)
- synapse on respiratory centers
- stimulation
- minimally active at rest
- respond to changes in arterial blood concentrations
- decreases in PO2
- increases in PCO2
- decreases in pH
- effect: increases blood flow to vital organs (brain and heart) when PO2 is low
- stimulates VC center: ↑ TPR gives ↑ MABP
- stimulates CA center: ↑ CO gives ↑ MABP
cardio-pulmonary reflexes
- overview
- receptors: imbedded in walls of the heart, large thoracic vessels, and lungs
- effect: modify vasomotor tone, heart rate, breathing
- innervation: afferents project with the vagus nerve
- ventricular receptors
- activation: greater than normal increases in diastolic or systolic pressure
- effect: strong depressor
- Bezold-Jarisch reflex
- severe depressor response caused by ventricular distension
- results in hypotension, bradycardia, and even fainting (may explain fright response in some)
- hypertension can make a person more susceptible to evoking the reflex
- somatic afferent reflexes
- types of responses
- pressor response: increases in blood pressure and heart rate
- depressor response: decreases in blood pressure and heart rate
- stimulation of somatic afferents generally cause a pressor response
- example: increased BP, heart rate in response to pain
- some have depressor responses, though the mechanism and function is unknown
summary of regulation
- baroreceptor reflex: dominates control
- (+) CI: ↓ HR directly reduces HR (M-ACh)
- (–) VC: ↓ TPR less arterial, venous vasoconstriction (α1 adrenergic)
- (–) CA: ↓ HR, contractility less SA node, myocyte stimulation (β1 adrenergic)
TABLE: Receptors in the Cardiovascular System
| location | action |
M-ACh (M1) | SA node | ↓ heart rate |
N-ACh (ganglionic) | autonomic ganglia | postganglionic EPSP |
α1 adrenergic | arterioles, veins | vasoconstriction |
β1 adrenergic | SA node cardiac muscle cells | ↑ heart rate ↑ contractile strength |
β2 adrenergic | some arterioles | vasodilation |
guanylyl cyclase | arterioles | vasodilation |
- receptor affinities
- norepinephrine: strong with α1, β1 (α and β)
- epinephrine: strong with β2, β1 (primarily β)
- mathematical relationships
- influences on stroke volume
- ↑ preload (HR): (–) effect
- ↑ afterload (MABP) (–) effect
- ↑ contractility (β1 stimulation): (+) effect
- reflex can be overridden
- emotions
- Cushing’s phenomenon (central chemoreceptors)
- peripheral chemoreceptors
- cardiopulmonary reflexes
- volume receptors (JGA in the kidney)
- local metabolites
Arterial Blood Pressure and Pulse
measurement of arterial blood pressure
- sphygmomanometry: most common method of measuring arterial blood pressure
- cuff pressure is increased above arterial blood pressure, occluding the pulse
- systolic: spurting of blood into arteries, causing audible turbulence and palpable radial pulses
- diastolic: reestablishment of laminar flow, causing loss of turbulence
- Korotkoff’s sounds: sound of turbulent flow heard during measurement of blood pressure
- average values
- young adult males: 120/80
- young adult females: 110/70
arterial pressure wave
- arterial pulse wave: propagating expansion of the arterial walls
- initiated at the root of the aorta upon ejection of a stroke of blood
- rate: 5-15 m/s (faster than flow velocity of 0.3-0.5 m/s)
- length: 5-7 m (longer than the longest single path in the cardiovascular system)
- can be felt upon palpation of an artery
- partially reflected by arterial bifurcations, small caliber vessels deep in arterial tree
- normally, only arrive back at root after aortic valve has closed
- with stiffened arterial tree, velocity is increased
- can arrive back at root while aortic valve is still open
- increases peak systolic pressure, pulse pressure
Capillary Function
anatomical considerations
- size
- internal diameter: 8 μm or less
- length: 0.5 to 1.0 mm
- density: correlates with metabolic activity of the tissue
- heart muscle: 2500-4000 capillaries / mm3
- skin: 100 capillaries / mm3
- pores: slit-like openings in capillary walls
- found at junctions of endothelial cells
- vary in size and number in different capillaries
- large: liver and marrow (allow passage of proteins in liver, RBCs in marrow)
- small: small (reduce, prevent loss of proteins and cellular elements from the IV space)
- occupy only about 0.02% of capillary surface area
movement of substances across the capillary wall
- diffusion: passive movement across a concentration gradient
- water soluble, fat insoluble: limited to diffusion through pores (inorganic ions, water, glucose, urea)
- fat soluble: can pass across the wall at any point (O2, CO2)
- responsible for vast majority of substance transfer
- filtration/reabsorption: movement due to pressure differences between lumen, interstitial fluid space
- fluid (filtrate) moves through the pores, carrying all solutes small enough to pass through
- mechanism
- pressure components
- hydrostatic pressure: capillary blood pressure (tissue hydrostatic pressure assumed to be zero)
- causes filtration, opposes reabsorption
- declines steadily along the length of the capillary (~32 to ~15 mmHg)
- oncotic pressure: osmotic pressure difference between plasma, interstitial fluid
- develops due to a difference in protein concentration between the fluids
- ~25 mmHg
- capillary exchange
- filtration: initial segment of the capillary (hydrostatic pressure exceeds oncotic, tissue pressures)
- reabsorption: final segment of the capillary (oncotic, tissue pressures exceed hydrostatic pressure)
- responsible for only a small portion of substance transfer, relative to diffusion
- causes of edema
- abnormal, sustained rise in systemic pressure
- reabsorption is reduced, resulting in edema if this exceeds the capacity of the lymphatics to drain fluid
- secondary to several cardiovascular diseases
- decrease in [plasma protein]
- oncotic pressure falls, causing a decrease in the force opposing filtration and promoting reabsorption
- secondary to starvation, kidney diseases, or liver diseases
- abnormally high permeability of the capillary wall
- filtration is increased
- secondary to chemicals such as histamine, bacterial toxins
- obstruction of lymphatic vessels
- drainage of the interstitial fluid space is decreased
- secondary to tumors, surgical complications, or parasites / infections
control of capillary blood flow
- control point: pre-capillary sphincter
- contraction: narrows opening, restricting passage of blood
- relaxation: expands opening, allowing greater passage of blood
- control primarily involves local metabolites rather than nerve activity
- vasomotion: rhythmic contraction and relaxation of pre-capillary sphincters
- spontaneously occurs even during tissue rest, constant metabolism
- due to highly localized changes in metabolite concentration
The Systemic Venous System
effects of gravity on distribution of venous blood
- gravity works against adequate circulation
- standing human: 70% of systemic circulation below the level of the heart
- gravity increases pressure of blood in direct proportion to distance below the heart
- gravity decreases pressure of blood in direct proportion to distance above the heart
- in venous return, gravity is potentially detrimental
- causes distension of systemic veins
- can allow pooling of blood, reducing cardiac output
- pressure alone can drive venous return in the recumbent individual
- pressure at entrance to veins: 15 mmHg
- pressure near RA: ~0 mmHg
- accessory mechanisms are needed for venous return in the upright individual
accessory factors promoting venous return in upright humans
- neurally-induced contraction of venous smooth muscle
- drive: sympathetic adrenergic vasoconstrictor neurons
- venous capacity is kept from increasing, blood does not accumulate
- pumping action of skeletal muscles
- valve: flaps of endothelial tissue that prevent backflow in the veins
- localized primarily to the limbs
- pumping of skeletal muscles causes unidirectional movement back towards the heart
- respiratory pump
- inspiration: drives return towards the heart
- enlarged thorax: fall in intrathoracic pressure
- large veins near the heart are thin enough that this reduces IV pressure
- creates a pressure gradient that favors flow of blood from extrathoracic regions
- descent of the diaphragm: rise in abdominal pressure, further increasing return
- expiration: backflow prevented by valves
venous (jugular) pulse
- external jugular veins: exhibit pulsations in the neck during each beat
- result from transient RA pressure increases
- contraction: a wave
- ventricular filling/release (bulges affect atria): c wave, x descent
- atrial filling/release: v wave, y descent
- especially evident when the head is in a lower position than the feet
- certain valvular defects, cardiac arrhythmias can predictably alter jugular pulse
The Pulmonary Circulation
hemodynamics of the pulmonary circulation
- pressures
- right ventricle systolic: 22-25 mmHg diastolic: 0-5 mmHg
- pulmonary artery: systolic: 22-25 mmHg diastolic: 8-10 mmHg
- pulmonary capillary: 6-8 mmHg
- left atrium: 5-7 mmHg
- flow
- blood flow is necessarily identical to the amount flowing through the systemic system
- driven by a small pressure gradient
- pulmonary arteries are shorter, wider than systemic counterparts
- resistance of pulmonary system is thus quite low
- high distensibility of the pulmonary system: illustrations
- cardiac output
- resting: 5 L/min
- exercising: 25 L/min
- accompanied primarily by enlarging of pulmonary vessels, rather than increase in pulmonary pressure
- surgical removal of one lung
- results in diversion of entire normal cardiac output to one lung
- pulmonary pressure still does not increase, again due to distensibility of the vessels
pulmonary artery (capillary) wedge pressure
- clinically useful
- filling pressure for the left ventricle
- determines left ventricular cell lengths at end-diastole
- difficult measurement to make
- pass a catheter into R side of the heart via systemic veins
- pass it into pulmonary circulation until it wedges in a small vessel
- recorded pressure is close to that of the L atrium
distribution of blood within the lungs
- highly susceptible to gravity
- pressures within circulation are low
- vessels are distensible
- pressure varies with position relative to heart
- apex: above the heart; relatively lower pressure
- base: below the heart; relatively higher pressure
- amount of blood perfusing these regions differs in a resting person, can vary more with upright individual
filtration/reabsorption in the lungs
- normal individuals: alveoli are “dry”
- pulmonary capillary pressure less than plasma oncotic pressure
- interstitial fluid volume remains normal
- pulmonary edema: accumulation of fluid in the interstitium and alveolar space
- commonly caused by left heart failure, which causes blood pooling in the pulmonary circulation
- can also be caused by mitral, aortic valve stenosis
blood volume in lungs
- pulmonary blood volume: 15-20% of total blood volume
- varies slightly with changes in body position
- largest when an individual is recumbent
- smallest when upright
- pulmonary edema manifests more when an individual is recumbent
regulation of pulmonary blood flow
- sympathetic innervation
- sympathetic vasoconstriction
- function: not well understood; may not be important
- local regulatory mechanisms
- hypoxia: vasoconstriction (opposite that in systemic circulation)
- must develop in the air passages, not in the blood
- acts to reduce flow of blood through regions in which O2 supply is inadequate for exchange
- high O2: vasodilation
- can, to some degree, act as a reservoir for blood
- can accept or give up significant quantities of blood
- can aid cardiac filling for a few beats or help maintain appropriate capacity-volume relationship
Thank you for sharing such wonderful information! When it comes to health, there is nothing more important than managing to eat healthy food and doing exercise regularly.
ReplyDeleteHealth Jobs Australia